• +31 (0) 594 696 131
  • sales@eurotronbenelux.nl
  • Inloggen
  • Home
  • Producten
      • Druk Kalibratoren
      • Automatische Druk Kalibratoren
      • Digitale druk indicators
      • Druk controllers
      • Multifunctionele Kalibratoren
      • Atex gecertificeerde instrumenten
      • Stikstof koffers
      • Handpompen
      • Loop Calibrators
      • Hart Communicators
      • Marine Kalibratie Kits
      • Temperatuur kalibratoren
      • Software
      • Druk Sensoren
      • Manometers
      • Recorders
      • Temperatuur sensoren
      • Flowmeters
      • Warmtebeeld cameras
      • Gasdetectie
      • Rookgas analysers
      • Vocht kalibratoren
      • Relatieve vocht sensoren
      • Dauwpunt transmitters
      • Signaalconditionering
      • Infrarood temperatuur
      • Accessoires
      • Testbanken
      • IoT Oplossingen
      • Druk modules
  • Merken
      • Druck
      • Additel
      • Process Sensing Technolgies / Michell Instruments
      • Ralston Instruments
      • PR Electronics
      • Eurotron Instruments
      • Optris
      • Wika
      • Fluke
      • MSA
      • Seitron
      • STIKO
      • Panametrics
      • Minimess
      • Setra
      • ERFI
      • AVIC
      • Hikmicro
  • Verhuur
  • Kalibratie
  • Contact
  • item(s)
×

Offerte aanvraag

DPI 880


DPI 880
Home / Producten / DPI 880

DPI 880

Prijs op aanvraag

De DPI 880 is een compact en eenvoudig te gebruiken instrument voor het testen, configureren en kalibreren van vrijwel alle proces parameters. Het instrument is 35% kleiner dan concurrerende modellen. Het windows-achtige menu gestuurde display biedt u een eenvoudige bediening van het instrument met weinig knoppen en is daarmee simpel en eenvoudig te begrijpen. De DPI 880 kan worden uitgebreid met een datalog optie waarmee u geen extra datalog instrumenten in het veld hoeft mee te nemen.

Offerte

 
  • Productbeschrijving
  • Extra informatie
  • Video
  • Downloads
  • De DPI 880 is een compact en eenvoudig te gebruiken instrument voor het testen, configureren en kalibreren van vrijwel alle proces parameters. Het instrument is 35% kleiner dan concurrerende modellen. Het windows-achtige menu gestuurde display biedt u een eenvoudige bediening van het instrument met weinig knoppen en is daarmee simpel en eenvoudig te begrijpen. De DPI 880 kan worden uitgebreid met een datalog optie waarmee u geen extra datalog instrumenten in het veld hoeft mee te nemen. De multifunctionele kalibrator DPI 880 biedt u de belangrijkste kalibratie parameters in een compact instrument. Het instrument is nauwkeurig en met een enkele druk op de knop stelt u het instrument in op de te meten of te simuleren waarde. De DPI 880 kan onder andere switch tests uitvoeren, daarnaast kunt u thermokoppel en RTD signalen meten en simuleren. Voor het kalibreren van transmitters kunt u mA signalen meten en het instrument onder test voorzien van 24V voedingsspanning. De ingebouwde 250 Ohms weerstand kunt u inschakelen als u Hart transmitters wilt kalibreren.

    Kenmerken

    • Meten en simuleren van mA, mV, ohms, frequentie en pulsen
    • Meten en simuleren van 8 RTDs en 12 thermokoppels
    • 32 IDOS® ‘Plug-en-Play’ Druk modules van 10 inH2O tot 10,000 psi (25 mbar tot 700 bar)
    • Automatisch switch test en druk lek test
    • 24 V voedingsspanning
    • Datalog optie
    • Compact, eenvoudig in gebruik, draagbaar
    • Met één hand te bedienen.

    Toepassingen

    • Test en onderhoud
    • Transmitter kalibratie
    • Loop set-up en diagnose
    • Switch, trip en alarm verificatie
  • General specifications

    Electrical connection

    4mm sockets and mini-jack thermocouple socket

    Calibrated temperature

    50°F to 86°F (10°C to 30°C) unless otherwise stated

    Operating Temperature

    14°F to 122°F (-10°C to 50°C) unless otherwise stated Temperature coefficient 14°F to 50°F, 86°F to 122°F 0.0017%FS/°F (-10°C to 10°C, 30°C to 50°C 0.003%FS/°C) For ohms 14°F to 50°F, 86°F to 122°F 0.0028%FS/°F (-10°C to 10°C, 30°C to 50°C 0.005%FS/°C)

    Storage Temperature

    -4°F to 158°F (-20°C to 70°C)

    Humidity

    0% to 90% non-condensing, Def Stan 66-31, 8.6 Cat III

    Shock and Vibration

    BS EN61010:2001, Def Stan 66-31, 8.4 Cat III

    EMC

    BS EN61326-1:1998 + A2:2001

    Safety

    Electrical BS EN61010:2001. Pressure Equipment Directive (PED), Class SEP. CE marked

    Display

    Graphic LCD with backlight.

    Size (l x w x h) and Weight

    7.1 in x 3.3 in x 2 in (180 mm x 85 mm x 50 mm), 15 oz (425 g)

    Batteries

    3 AA alkaline, >50 hours measure, >10 hours 24V source

     

    Electrical specification

     

    Measure accuracy Source accuracy

    0 to 24.000 mA

    0.02% rdg + 2 counts

    0 to 55.000 mA

    0.02% rdg + 3 counts

    0 to 120.00 mV

    0.02% rdg + 2 counts

    0 to 12.000 V

    0.02% rdg + 2 counts

    0 to 30.000 V

    0.03% rdg + 2 counts

    0 TO 4000.0 Ω

    0.1 to 1.3 Ω

    Switch detection

    Open and closed, 2 mA current

    Loop power

    24 V +/-10% (35 mA maximum)

    HART mA loop resistor

    250 Ω (menu selection)

     

    Frequency specification

     

    Measure accuracy Source accuracy

    0 to 999.999 Hz

    0.003% rdg + 2 counts 0.003% rdg + 0.0023 Hz

    0 to 50.0000 kHz

    0.003% rdg + 2 counts 0.003% rdg + 0.0336 Hz

    0 to 999999 cpm

    0.003% rdg + 2 counts

    0 to 59999 cpm

    0.003% rdg + 0.138 cpm

    0 to 999999 cph

    0.003% rdg + 2 counts

    0 to 99999 cph

    0.003% rdg + 0.5 cph

    Output waveform

    Square wave (zero crossing)

    Voltage input

    30 V maximum

    Trigger level

    0 to 12 V resolution 0.1V

    Output amplitude

    0 to 12 VDC +/- 1% (10 mA maximum)

     

    0 to 12 VAC pk-pk +/- 5% (10 mA maximum)

     
    Temperature specification RTD

    Measure and Simulate

    Standard

    *Accuracy

    Range

    Pt 50 (385)

    IEC 751

    0.9°F (0.5°C)

    -328°F to 1562°F (-200°C to 850°C)

    Pt 100 (385)

    IEC 751

    0.45°F (0.25°C)

    -328°F to 1562°F (-200°C to 850°C)

    Pt 200 (385)

    IEC 751

    1.08°F (0.6°C)

    -328°F to 1562°F (-200°C to 850°C)

    Pt 500 (385)

    IEC 751

    0.72°F (0.4°C)

    -328°F to 1562°F (-200°C to 850°C)

    Pt 1000 (385)

    IEC 751

    0.36°F (0.2°C)

    -328°F to 752°F (-200°C to 400°C)

    D 100 (392)

    JIS 1604-1989

    0.45°F (0.25°C)

    -328°F to 1202°F (-200°C to 650°C)

    Ni 100

    DIN 43760

    0.36°F (0.2°C)

    -76°F to 482°F (-60°C to 250°C)

    Ni 120

    MINCO 7-120

    0.36°F (0.2°C)

    -112°F to 500°F (-80°C to 260°C)

    Ohms

     

    0 to 4000

    0.1 to 1.3 Ω

     

    * Mid range figure quoted

    Excitation: 0.2 to 0.5 mA measure, 0.05 to 3 mA simulate Pulse excitation currents minimum duration 10 ms

    Temperature specification Thermocouple

    Type

    Standard

    *Accuracy

    Range

    K

    IEC 584

    1.1°F (0.6°C)

    -454°F to 2502°F (-270°C to 1372°C)

    J

    IEC 584

    0.9°F (0.5°C)

    -346°F to 2192°F (-210°C to 1200°C)

    T

    IEC 584

    0.6°F (0.3°C)

    -454°F to 752°F (-270°C to 400°C)

    B

    IEC 584

    1.8°F (1.0°C)

    32°F to 3308°F (0°C to 1820°C)

    R

    IEC 584

    1.8°F (1.0°C)

    -58°F to 3214°F (-50°C to 1768°C)

    S

    IEC 584

    2.5°F (1.4°C)

    -58°F to 3214°F (-50°C to 1768°C)

    E

    IEC 584

    0.7°F (0.4°C)

    -454°F to 1832°F (-270°C to 1000°C)

    N

    IEC 584

    1.1°F (0.6°C)

    -454°F to 2372°F (-270°C to 1300°C)

    L

    DIN 43710

    0.6°F (0.3°C)

    -328°F to 1652°F (-200°C to 900°C)

    U

    DIN 43710

    0.6°F (0.3°C)

    -328°F to 1112°F (-200°C to 600°C)

    C

     

    1.8°F (1.0°C)

    32°F to 4199°F (0°C to 2315°C)

    D

     

    1.8°F (1.0°C)

    32°F to 4514°F (0°C to 2490°C)

    mV

     

    0.2%rdg + 0.01%FS

    -10 to 75 mV

    *Mid range figure quoted

    Cold Junction Error 0.4°F (0.2°C) maximum for 86°F (30°C) change in ambient temperature
     

  •  
  • Documents:
    Filename Upload date Size
    DPI 880 Datasheet 2023.8.17 5.3 MB
    DPI880 Manual 2019.3.11 4.4 MB



     

Nieuwsbrief

    Aanmelden nieuwbrief

MERKEN

  • > Druck
  • > Additel
  • > Process Sensing Technolgies / Michell Instruments
  • > Ralston Instruments
  • > PR Electronics
  • > Eurotron Instruments
  • > Optris
  • > Wika
  • > Fluke
  • > MSA
  • > Seitron
  • > STIKO
  • > Panametrics
  • > Minimess
  • > Setra
  • > ERFI
  • > AVIC
  • > Hikmicro

Verhuur

  • Wist u dat u Kalibratie, Test & Meet apparatuur bij Eurotron Instruments kunt huren?
    • + Ideaal voor een tijdelijk meetproject
    • + Meetapparatuur korte periode nodig
    • + Meetapparatuur is gekalibreerd
    • + Geen investering nodig
    • + Voor een specifieke meting
    • + Altijd de meest moderne apparatuur

OVER ONS

Eurotron heeft haar succes te danken aan meerdere productgroepen die op verschillende en zeer veeleisende markten worden gericht: kalibratie apparatuur, druk- en temperatuursensoren, infrarood temperatuursensoren en gasdetectie apparatuur.

KLANTENSERVICE

  • Privacy Policy
  • Verzending
  • Leveringsvoorwaarden
  • Kalibratieservices
  • Nieuwsbrief
  • Contact

VOORDELEN

  • Ruim aanbod
  • Jaren ervaring
  • Topmerken
  • Kennis in huis
  • Verkoop en verhuur
  • Eigen accountmanager
  • Wereldwijd leverbaar

Contact

sales@eurotronbenelux.nl
+31 (0) 594 696 131
Vossenkamp 7a 9351VR Leek
Netherlands

KvK Groningen 02098837
BTWnummer NL8179.84.859.B01

© 2021 Eurotron , Alle rechten gereserveerd | Ontworpen en ontwikkeld door AYO MEDIA

icon icon icon